Ventilation Hood Installation Instructions Designer Hoods
CFM 1200 IN-HOOD FAN WALL APPLICATION– 10” TRANSITION 10
CFM 1200 IN-HOOD FAN CHIMNEY AND ISLAND APPLICATION– 10” TRANSITION 10
INSTALLATION WARNING: To reduce the risk of fire, use only metal ductwork. 1. Decide the placement of the ductwork between the hood and the outside o
ISLAND DUCT COVER INSTALLATION 12
ISLAND HOOD DUCT WORK INSTALLATION 1. Cut a 10” diameter opening in the ceiling to accommodate the duct work necessary for proper ventilation. 2. Tra
REMOTE FAN ROOF MOUNT OR WALL MOUNT 14
15
CHECK LOCATION • If your installation has been roughed-in (including ductwork and wiring), be certain there is nothing in the way of the mounting, pi
TRANSITION INSTALLATION AND REMOVAL 1. The liner is shipped with the back-panel and the transition attached. 2. The transition is shipped upside-down
INSTALLING METAL LINERS 1. If the “EZ Optional Trim Kit” will be used, it must be installed prior to mounting the metal liner to the hood shell. Use
TABLE OF CONTENTS Safety Instructions 1 Safety Procedures 2 Wall Hood Installation Installation Instructions 3 Wall Hood – 600 CFM I
ELECTRICAL CONNECTIONS 1. Install three wires: black, white and green (#16 AWG) in ½” conduit from the service panel to the hood junction box. Power
COMPACT METAL LINER SLOPED SIDES (CMLSS) 23
METAL LINER SLOPED SIDES (MLSS) 24
PROFESSIONAL METAL LINER SLOPED SIDES (PMLSS) 25
METAL LINER FLAT SIDES (MLFS) 26
CHECK THE INSTALLATION LOCATION • If your installation has been roughed-in (including duct work and wiring), be certain there is nothing in the way o
INSTALLING CHIMNEY STYLE HOODS 1. Position the Chimney Hood on its back and locate the transition inside the Chimney Hood; remove the (4) #8 x ½” self
INSTALLING CHIMNEY STYLE HOODS (continued) 8. Electrician may complete electrical connection to hood making the connection at the box inside the hood
ALTERNATE INSTALLATION FOR A CHIMNEY STYLE HOOD In certain situations the installer may opt for a different installation sequence. The alternate sequ
INSTALLING A CHIMNEY STYLE HOOD WITH A REAR DISCHARGE THROUGH DUCT COVER The Chimney Style Hood can adapt to a rear discharge application but with the
PLEASE READ COMPLETE INSTRUCTIONS BEFORE PROCEEDING. INSTALLATION MUST COMPLY WITH ALL LOCAL CODES. IMPORTANT: Save these instructions for the lo
INSTALLING A CFM600 FAN IN A 30” WIDE CHIMNEY STYLE HOOD These instructions are only applicable when installing a CFM600 fan in a 30” wide chimney sty
WIRING A REMOTE FAN When using a remote fan with a chimney style hood, follow the instructions noted below. NOTE: The chimney style hood is designed
BAFFLE FILTERS, GREASE TROUGHS AND LIGHTS BAFFLE FILTERS Your baffle filters come with knobs to aid in filter placement and removal. Grab the knobs
CLEANING RECOMMENDATIONS Brushed Stainless Steel, Hammered Stainless Steel, European Black Steel and Millennium Disk Stainless The Brushed Stainless
TROUBLESHOOTING TIPS PROBLEM OR CONDITION Fans and lights do not operate POSSIBLE SOLUTION • A fuse may be blown or the circuit breaker tripped. Re
SAFETY PROCEDURES FOR INSTALLING YOUR NEW PRIZER HOOD (continued) CAUTION – To reduce the risk of fire, electric shock, or injury to people, observe
1. The hood is shipped with the back panel and the transition. (Note: The transition is shipped upside down within the hood and can be flipped for re
WALL HOOD INSTALLATION (continued) 1. Add 2” x 4” wood framing block to aid in securing the top and rear of the hood to the wall. (See Figure 6) 2.
CFM 600 IN-HOOD FAN WALL APPLICATION – 8” ROUND COLLAR 7
CFM 600 IN-HOOD FAN WALL APPLICATION – 8” TRANSITION 8
CFM 600 IN-HOOD FAN CHIMNEY AND ISLAND APPLICATION– 8” TRANSITION 9